440R-B23020 Guardmaster MSR5T Safety Relay.
Function Single channel input, can be connected to 1NC or 2NC contacts Automatic/manual/monitored reset is optional; The reset circuit X1-X2 must be connected in series with the normally closed point of the external contactor to achieve contact welding monitoring Once the input is disconnected or the circuit fails, the three safety contacts (13-14, 23-24, 33-34) will immediately disconnect, and the one auxiliary normally closed (41-42) will be used for status indication Electrical specifications Power supply: 24 V AC/DC (0.85-1.1 Un) Safe output: 3NO, 2 A/250 V AC (AC-15); Auxiliary output: 1NC, 2A Input impedance: ≤ 250 Ω Response time: ≤ 30 ms; electrical lifespan 1 × 10 ? times security level ISO 13849-1 Cat.4/PL e, IEC 61508/EN 62061 SIL 3 (maximum PL e achievable in single channel architecture, depending on peripheral wiring) Installation and Environment 35mm DIN rail, housing IP40, terminal IP20 Working temperature -5...+55 ° C, humidity ≤ 90% RH, no condensation Terminal torque 0.6 N · m, wire 0.2... 2.5 mm 2; 2 A gG fuses need to be connected externally on the power supply side Typical Applications Redundant shutdown chain for single machine emergency stop, safety door, and limit switch As an extension head of the MSR series, cascaded EM/EMD modules add more delay or instantaneous output Suitable for occasions requiring Cat.4/PL e, simple wiring, and compact space“
Indique referencia, cantidad y fecha objetivo. Confirmamos stock o plazo, ofrecemos alternativa si la línea no está disponible y emitimos factura comercial con código arancelario.
Envíe su BOM o números de parte; respondemos en un día hábil.
Contactar