Power level: Continuous current 4 A (peak 10 A), corresponding to a typical output power of 1.8 kW Input voltage: 460 V AC three-phase, DC bus 675 V Bus capacitance: 75 μ F, pre charging is managed uniformly by the left IAM module Security Integration: Supports STO (Safe Torque Off); If paired with a 6500 control module, it can be extended to safety functions such as SS1/SS2/SLS/SBC, in compliance with ISO 13849-1 PLe/SIL3 Connection and installation: Plug it into the 2094 PRx power rail, and other AM, bypass, or IPIM modules can continue to cascade on the right side The motor power, brake and feedback cables are led out through the bottom quick connect plug The module thickness is 55mm, and a ventilation space of ≥ 150mm should be left above and below Diagnosis/LED: Four color indicator lights for bus status, shaft fault, communication status, and safety status; Automatic recognition within Studio 5000, supporting one click replacement“
请提供型号、数量与目标交期。我们确认库存或交期,缺货时提供替代型号,并出具含海关编码的商业发票。